SF6 - Gas density monitoring

Trafag gas monitoring devices measure the gas density directly, i.e. SF6 Gas Density Monitors, with the unique gas density reference principle or the patented quartz tuning fork technology, i.e. SF6 Gas Density Sensors, or by combining both principles, i.e.SF6 Hybrid Gas Density Monitors. They thus offer the most reliable solution on the market by directly measuring theSF6 gas density. Trafag guarantees outstanding accuracy and operation in the widest temperature range on the market. 

Maximilian Grudin

Produktområde:
Tryck- och temperaturgivare

Se kontaktuppgifter

ProduktApplikationTeknikMätområdeUtsignalTemperaturområdeDokumentation
8774 Gas Density Sensor with analogue and PWM output
8774 Gas Density Sensor with analogue and PWM outputHigh and Medium voltage technologyOscillating quartz measurement0...60 kg SF6 /m3 10 ... 253 HzDigital: current pulses Density signal: pulse frequency 10...292 Hz (range 0...60 kg SF6/m3) Analogue: 6.5...20 mA Density signal: current loop 10...275 Hz (range 0...56.1 kg SF6/m3)Permanent -40... +70°C (max. 200h per year) -55... +70°CDatabladManual
8775 Gas Density Sensor RS485/MODBUS
8775 Gas Density Sensor RS485/MODBUSHigh and Medium voltage technologyOscillating quartz measurement0...60 kg SF6 /m3 10 ... 253 HzRS485/Modbus (RTU)Permanent -40... +70°C (max. 200h per year) -55... +70°CDatabladManual
87x6 Gas Density Monitor
87x6 Gas Density MonitorHigh voltage switchgearReference gas measurementAbsolute: 0...1.1 MPa / (0...1100 kPa)Floating change-over contact-40°C...80°CDatabladManual
87x8 Gas density monitor for arctic temperatures
87x8 Gas density monitor for arctic temperaturesHigh voltage switchgearReferensgasAbsolute: 0...1,1 MPa / (0...1100 kPa)Floating change-over contact–60 ... +80°CDatabladManual
879x Hybrid Gas Density Monitor RS485/MODBUS
879x Hybrid Gas Density Monitor RS485/MODBUSHigh voltage switchgearMechanical monitoring: Principle: Reference gas measurement Electronic monitoring: Principle: Oscillating quartz measurementMechanical monitoring, measuring range absolute: 0...1.1 MPa (0...1100 kPa) Electronic monitoring/sensor, measuring range absolute: 0...0.85MPa SF6 @ 20°C 0...56.1 kg SF6 /m3RS485 / MODBUS-40°C...80°CDatabladManual
878x Hybrid Gas Density Monitor with analogue output
878x Hybrid Gas Density Monitor with analogue outputHigh voltage switchgearMechanical monitoring: Principle: Reference gas measurement Electronic monitoring: Principle: Oscillating quartz measurementMechanical monitoring, measuring range absolute: 0...1.1 MPa (0...1100 kPa) Electronic monitoring/sensor, measuring range absolute: 0...0.85MPa SF6 @ 20°C 0...56.1 kg SF6 /m3Floating change-over contact-40°C...80°CDatabladManual