SF6 - Gas density monitoring
Trafag gas monitoring devices measure the gas density directly, i.e. SF6 Gas Density Monitors, with the unique gas density reference principle or the patented quartz tuning fork technology, i.e. SF6 Gas Density Sensors, or by combining both principles, i.e.SF6 Hybrid Gas Density Monitors. They thus offer the most reliable solution on the market by directly measuring theSF6 gas density. Trafag guarantees outstanding accuracy and operation in the widest temperature range on the market.
Product | Application | Technology | Measuring range | Output | Temperature range | Documentation | |
---|---|---|---|---|---|---|---|
![]() |
8774 Gas Density Sensor with analogue and PWM output | High and Medium voltage technology | Oscillating quartz measurement | 0...60 kg SF6 /m3 10 ... 253 Hz | Digital: current pulses Density signal: pulse frequency 10...292 Hz (range 0...60 kg SF6/m3) Analogue: 6.5...20 mA Density signal: current loop 10...275 Hz (range 0...56.1 kg SF6/m3) | Permanent -40... +70°C (max. 200h per year) -55... +70°C | ![]() ![]() |
![]() |
8775 Gas Density Sensor RS485/MODBUS | High and Medium voltage technology | Oscillating quartz measurement | 0...60 kg SF6 /m3 10 ... 253 Hz | RS485/Modbus (RTU) | Permanent -40... +70°C (max. 200h per year) -55... +70°C | ![]() ![]() |
![]() |
87x6 Gas Density Monitor | High voltage switchgear | Reference gas measurement | Absolute: 0...1.1 MPa / (0...1100 kPa) | Floating change-over contact | -40°C...80°C | ![]() ![]() |
![]() |
87x8 Gas density monitor for arctic temperatures | High voltage switchgear | Reference gas measurement | Absolute: 0...1.1 MPa / (0...1100 kPa) | Floating change-over contact | –60 ... +80°C | ![]() ![]() |
![]() |
879x Hybrid Gas Density Monitor RS485/MODBUS | High voltage switchgear | Mechanical monitoring: Principle: Reference gas measurement Electronic monitoring: Principle: Oscillating quartz measurement | Mechanical monitoring, measuring range absolute: 0...1.1 MPa (0...1100 kPa) Electronic monitoring/sensor, measuring range absolute: 0...0.85MPa SF6 @ 20°C 0...56.1 kg SF6 /m3 | RS485 / MODBUS | -40°C...80°C | ![]() ![]() |
![]() |
878x Hybrid Gas Density Monitor with analogue output 2 | High voltage switchgear | Mechanical monitoring: Principle: Reference gas measurement Electronic monitoring: Principle: Oscillating quartz measurement | Mechanical monitoring, measuring range absolute: 0...1.1 MPa (0...1100 kPa) Electronic monitoring/sensor, measuring range absolute: 0...0.85MPa SF6 @ 20°C 0...56.1 kg SF6 /m3 | Floating change-over contact | -40°C...80°C | ![]() ![]() |