Products
We are specialists in position sensing, in other words feed back signal from a linear or rotary sensor. With our experience we will guide you to the best solution, no matter if you need some standard components from our stock or larger quantities of a customized sensor.
Pressure transmitters
Trafag transmitters are used for the sensing of pressure and the transmission of pressure proportional electrical signals.
Options
Trafag sensors are the basis of precise Pressure Transmitters.
Method of measuring
Steel sensors
Technology: Thin film on steel
Advantages:
Ceramic Sensors
Technology: Thick film on ceramic
Advantages:
Product | Application | Accuracy | Measuring range | Pressure connection | Sensor technology | Output | Documentation | |
---|---|---|---|---|---|---|---|---|
![]() |
Pressure transmitter NAH 8253 | Test benches | ±0,15%, ±0,1% FS | 0...2,5 to 0...600 Bar | G1/4'' male, et al. | Thin film on steel | 4-20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0,5...4,5 VDC ratiometric | ![]() ![]() ![]() |
![]() |
Pressure transmitter NAH 8254 - 20 kHz | Measuring and test benches | ±0,3% FS | 0...0,2 to 0...600 Bar | G1/4'' male, et al. | Thin-film-on-steel | 4...20 mA, 0.5...4.5 V ratiometric, 0...5 VDC | ![]() ![]() ![]() ![]() |
![]() |
Pressure transmitter CMP 8270 - CANopen | Test benches | ±0.5%, ±0.3%, ±0.15%, ±0.1% FS | 0...0.2 to 0...600 bar | G1/4'' male, et al. | Thin film on steel | CANopen bus protocol DS301/DS404 supports CAN 2.0A/B | ![]() ![]() ![]() |
![]() |
Pressure transmitter ESH 8845 – High accuracy | Test benches | ± 0,1, ± 0,05 % FS | 0...0.1 to 0...100 bar | G1/4 | Piezoresistive | 4...20 mA, 0...5 VDC, 0...10 VDC | ![]() ![]() |
![]() |
Pressure transmitter NAT 8252 | Hydraulics | ±0,5% FS | 0...2,5 to 0...600 Bar | G1/4'' male, et al. | Thin film on steel | 4...20 mA, 0.5...4.5 V, 0...5V, 1...5 V, 1...6 V, 0...10V, 0.1...10.1 V, 0,5...4,5 VDC ratiometrisk, 1 PNP, 2 PNP | ![]() ![]() ![]() |
![]() |
Pressure transmitter NAH 8254 | Hydraulics | ±0,3% FS | 0...0.2 to 0...600 Bar | G1/4'' male, et al. | Thin film on steel | 4...20 mA, 0.5...4.5 V, 0...5V, 1...5 V, 1...6 V, 0...10V, 0.1...10.1 V, 0,5...4,5 VDC ratiometrisk, 1 PNP, 2 PNP | ![]() ![]() ![]() |
![]() |
DPS 8381–Display Pressure Switch | Mobile hydraulics | ±0,5% FS | 0...2,5 to 0...600 bar | G1/4, et al. | Thin film on steel | 4..20 mA, 0..10 VDC, 0..5 V, 1..6 VDC, switchable mA or V | ![]() ![]() ![]() ![]() |
![]() |
FPT 8235 – Flush Membrane Transmitter | Mobile hydraulics | ±0,4 % FS | 0...1 to 0...100 bar | G1/2 | Thin film on steel | 4...20 mA, 0...5 V, 1...6 V, 0...10 V | ![]() ![]() |
![]() |
Pressure transmitter NAR 8258 - Railway | Railway | ±0,3% FS | 0...6 to 0...600 bar | G1/4” male, 1/4” NPT male, 7/16”-20UNF SAE4 male, et al. | Thin film on steel | 4...20 mA, 1 PNP, 2 PNP | ![]() ![]() |
![]() |
Pressure transmitter NSL 8257 | Low pressure | ±0,8%, ±0,5%, ±0,3%, ±0,15% FS | 0...0.2 to 0...2.5 bar | G1/4'' male, et al. | Thin film on steel | 4...20 mA, 0...10 VDC, 0...5 VDC, 0,5...4,5 VDC ratiometric | ![]() ![]() |
![]() |
Pressure transmitter ECT 8473 | Low pressure | ±1,0%, ±0,5%, ±0,3% FS | 0...0.1 - 0...40 bar | G1/4'' male, G1/4'' female, NPT 1/4'' male, G3/4 | Thick film on ceramic | 4...20 mA, 0...5 VDC, 0...10 VDC, 0.5...4.5 VDC ratiometric | ![]() ![]() |
![]() |
Pressure transmitter ECT 8472 | Aggressive media | ±0,5% FS | 0...1 to 0...400 bar | G1/4'' male, G1/4'' female, NPT 1/4'' male, G3/4. et al. | Thick film on ceramic | 4...20 mA, 0...5 VDC, 0...10 VDC, 0.5...4.5 VDC ratiometric | ![]() ![]() ![]() |
![]() |
Pressure transmitter ECTN 8477 | Aggresive media | ±1,0 %, ±0,5 %, ±0,3 % FS | 0...0.1 to 0...250 bar | G1/4'' male, G1/4'' female, G1/2 | Thick film on ceramic | 4...20 mA | ![]() ![]() ![]() |
![]() |
DPC 8380–Display Pressure Switch | Aggressive media | ±0,5% FS | 0...1 to 0...100 bar | G1/4” female/male, G1/2 | Thick film on ceramic | 4..20 mA, 0..10 V, 0..5 V, 1..6 VDC, switchable mA or V | ![]() ![]() ![]() ![]() |
![]() |
Pressure transmitter NAE 8256 | Shipbuilding | ±0,5%, ±0,3% FS | 0...6 till 0...600 bar | G1/4'' male, et al. | Thin film on steel | 4...20 mA | ![]() ![]() ![]() |
![]() |
Pressure transmitter EPN 8288 | Shipbuilding | ±0,5%, ±0,3% FS | 0...2.5 to 0...600 bar | G1/4'', G1/2'', R1/4'', et al. | Thin film on steel | 4...20 mA, 0...10 VDC | ![]() ![]() ![]() ![]() |
![]() |
Pressure transmitter EPN 8298 | Shipbuilding | ±0,5%, ±0,3% FS | 0...2.5 to 0...2500 bar | G1/4'', G1/2'', R1/4'', et al. | Thin film on steel | 4...20 mA, 0.5...4.5 VDC ratiometric | ![]() ![]() ![]() ![]() |
![]() |
Pressure transmitter NPN 8264 | Shipbuilding | ±0,5%, ±0,3% FS | 0...2.5 to 0...250 bar | G1/4'' female, Flange connection, et al. | Thin film on steel | 4...20 mA | ![]() ![]() ![]() |
![]() |
Pressure transmitter EXNT 8292 | ATEX & IECEx | ±0,5 %, ±0,3% FS | 0...0.4 to 0...2000 bar | G1/4'', G1/2'',1/4'' NPT, et al. | Thin film on steel | 4...20mA | ![]() ![]() |
![]() |
Pressure transmitter EXL 8432, Submersible | ATEX & IECEx | ±0,5%, ±0,3% FS | 0...0.2 till 0...10 bar | Type 1 f, M 10x1, Type 2 m, M 22x1 | Thick film on ceramic | 4...20 mA | ![]() ![]() |
![]() |
Pressure transmitter ECL 8439, Submersible | Shipbuilding, Process technology, Water treatment (wastewater, grey-water, drinking water), Seawater, Level of oils and fuels | ±0,5%, ±0,3% FS | 0...0.01 till 0...2 bar | - | Thick-film-on-ceramic | 4...20 mA | ![]() ![]() ![]() ![]() |
![]() |
Pressure transmitter NAL 8838, Submersible | Shipbuilding | ±0,5%, ±0,25%, ±0,1% FS | 0...0.1 to 0...25 bar | Open; Closed; G1/4 | Piezoresistive | 4...20 mA, 0...10 VDC | ![]() ![]() |
![]() |
DVB, diagnostic valve | -0.8 ... 100 bar | G1/4” female | ![]() ![]() | ||||
![]() |
MHDS Differential pressure transmitter | 75 mbar...420 bar | 1/4 -18 NTP stainless steel 1.4435 | Differential pressure transmitter | 4...20mA current loop,Hart-protocol optionally with 2 electronic limit contacts | ![]() ![]() | ||
![]() |
MHPS Pressure transmitter, heavy duty | 0,1...1000 bar | G 1/2,G 1/4B,G1/4A,1/2 NPT,1/4 NPT,M20x1,5 | Pressure transmitter | 4...20mA current loop,Hart-protocol optionally with 2 electronic limit contacts | ![]() |